Back to Withdrawn Sites List


Scope of Accreditation Withdrawn-   View and Print Scope of Accreditation Printable version

Note: Not all of the columns of the scope of accreditation displayed include data.
The only data displayed is that deemed relevant and necessary for the clear description of the activities and services covered by the scope of accreditation.
Grey text appearing in a SoA is additional freetext providing further refinement or information on the data in the preceding line entry.

ISO/IEC 17025 (2005)
Calibration
SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
Acoustical metrology - Acoustic equipment
Band pass filters;
Frequency response;
By methods of AS/NZS 4476;
for relative attenuation up to 80 dB
CAPABILITY
With Calibration and Measurement Capability of-
0.7 dB for relative attenuation up to 80 dB

Sound level meters;
Electrical response;
By methods of IEC 61672-3;
CAPABILITY
With Calibration and Measurement Capability of-
0.12 dB


Electrical response;
By methods of AS 1259.1; By methods of AS 1259.2; By methods of IEC 61672-3;
AS 1259.1: 1990
AS 1259.2: 1990
CAPABILITY
With Calibration and Measurement Capability of-
0.1 dB


Frequency response;
By methods of AS 1259.1; By methods of AS 1259.2; By methods of IEC 61672-3;
31.5 Hz to 12.5 kHz
CAPABILITY
With Calibration and Measurement Capability of-
0.13 dB from 31.5 Hz to below 8 kHz
0.15 dB at 8 kHz
0.19 dB at 12.5 kHz (AS 1259)
Acoustical metrology - Acoustic equipment
Audiometers;
Frequency response;
By methods of AS/IEC 60645.1;
AS/IEC 60645.1 Clauses 6.1.2, 6.1.3, 8.3 (accuracy of sound level pressure only), 8.4.4, 8.6.2, 8.6.3, 13.5, 13.6.1 and 13.6.2. Type 4 Screening Audiometers only (including calibration in the field)
including on site calibrations



CAPABILITY
With Calibration and Measurement Capability of-
0.11% for Frequency
Acoustical metrology - Acoustic equipment
Audiometers;
Total harmonic distortion;
By methods of AS/IEC 60645.1;
AS/IEC 60645.1 Clauses 6.1.2, 6.1.3, 8.3 (accuracy of sound level pressure only), 8.4.4, 8.6.2, 8.6.3, 13.5, 13.6.1 and 13.6.2. Type 4 Screening Audiometers only (including calibration in the field)
including on site calibrations



CAPABILITY
With Calibration and Measurement Capability of - 
0.7% for THD+Noise
Acoustical metrology - Acoustic equipment
Audiometers;
Sound pressure level;
By methods of AS/IEC 60645.1;
AS/IEC 60645.1 Clauses 6.1.2, 6.1.3, 8.3 (accuracy of sound level pressure only), 8.4.4, 8.6.2, 8.6.3, 13.5, 13.6.1 and 13.6.2. Type 4 Screening Audiometers only (including calibration in the field)
between 500 Hz and 8 kHz
including on site calibrations



CAPABILITY
With Calibration and Measurement Capability of-
0.23 dB or sound pressure level between 500 Hz and 8 kHz

Dose meters for sound;
Electrical response; Frequency response; Noise exposure/dose;
By methods of AS 2399;
63 Hz to 8 kHz
CAPABILITY
Periodic calibration of Cirrus Research dosebadge Noise dosimeters and personal sound exposure meters
With Calibration and Measurement Capability of - 
0.11 dB from 63 Hz to 125 Hz
0.09 dB from above 250 Hz to 2 kHz
0.12 dB from above 4 kHz to 8 kHz
0.12 dB for electrical tests
5% for noise dose
Acoustical metrology - Acoustic standards and reference equipment
Acoustic calibrators - Multi frequency; Acoustic calibrators - Single frequency;
Pressure sensitivity;
By methods of AS/IEC 60942;
AS/IEC 60942 Annex B - Periodic Tests for sound pressure level at nominal 1 kHz
CAPABILITY
With Calibration and Measurement Capability of-
0.2 dB for sound pressure level at nominal 1 kHz


Distortion;
By methods of AS/IEC 60942;
AS/IEC 60942 Annex B - Periodic Tests
CAPABILITY
With Calibration and Measurement Capability of-
0.8% for total harmonic distortion


Frequency;
By methods of AS/IEC 60942;
AS/IEC 60942 Annex B - Periodic Tests
CAPABILITY
With Calibration and Measurement Capability of-
0.05% for frequency

ISO/IEC 17025 (2005)
Manufactured Goods
SERVICEPRODUCTDETERMINANTTECHNIQUEPROCEDURELIMITATION / RANGE
Acoustic performance evaluation of products
Acoustic enclosures and booths;
Sound absorption; Sound insulation; Sound pressure level; Sound transmission;

WorkCover WA Acoustical Environment for Audiometry